Carel · La Mercy
Temperature Mapping & Validation for Carel Systems in Macadamia Processing | Dube TradePort
Multi-probe mapping and documented validation for audited storage. We support Carel electronic controllers and humidity systems running R404A, R134a in macadamia processing across Dube TradePort and Dube TradePort SEZ.
Technical highlights
SAQCC Gas certified temperature mapping & validation
SANS 10147 pressure and gas compliance, genuine Carel OEM parts and rapid dispatch to Dube TradePort.
- SAQCC Gas registered technicians handling R404A, R134a
- SANS 10147 pressure vessel and installation compliance
- Genuine Carel OEM parts — Carel EVD Evolution drivers, NTC/ratiometric probes and pGD terminals
- Study over 24–72 hours to Dube TradePort, La Mercy
Common maintenance vectors
What we find on these systems
- Stratification at high level
- Door-opening excursions
- Probe placement and calibration
- EVD driver alarms from a mis-set superheat target
- Corroded probe terminations in high-humidity rooms
- Lost parameter sets after unprotected power dips
Dynamic specifications
Macadamia Processing duty on Carel plant
Dry-store climate control and kernel holding rooms
| Typical system duty | +8 °C to +15 °C (Client setpoint band, typically +2 °C to +8 °C) |
|---|---|
| Design humidity | 55–65% RH |
| Recommended gas / pressure class | R404A, R134a — handled by SAQCC Gas registered technicians |
| Equipment platform | Carel Electronic controllers and humidity systems — pCO/pRack controllers, EVD Evolution driver, humiSteam humidification |
| Compliance frameworks | HACCP, FSSC 22000, SANS 10147, SAQCC Gas registration |
| OEM parts held | Carel EVD Evolution drivers, NTC/ratiometric probes and pGD terminals |
| Service deliverable | Mapping report with hot/cold spot layout and IQ/OQ/PQ pack |
| Response / lead time | Study over 24–72 hours |
| Location hub | Serving Dube TradePort SEZ, Dube AgriZone and surrounds off the N2 / King Shaka corridor |
Local context
Working in Dube TradePort
We service Dube TradePort SEZ, Dube AgriZone and the surrounding blocks of Dube TradePort, La Mercy, with access off the N2 and King Shaka corridor. Sub-tropical coastal humidity keeps wet-bulb temperatures high year-round, which raises evaporative condenser duty and accelerates coil corrosion.
Dehumidification-dominant load with low sensible duty Moisture pickup drives rancidity and kernel downgrade
Compliance
Documentation you receive
- HACCP
- FSSC 22000
- SANS 10147
- SAQCC Gas registration
- Mapping report with hot/cold spot layout and IQ/OQ/PQ pack
FAQ
Carel temperature mapping & validation in Dube TradePort
How fast can a technician service Carel equipment at a macadamia processing site in Dube TradePort?
Dube TradePort sits on the N2 and King Shaka corridor, so our La Mercy dispatch reaches most Dube TradePort SEZ sites inside a standard callout window. Emergency temperature mapping & validation runs 24/7 because moisture pickup drives rancidity and kernel downgrade.
Do you stock OEM components for Carel systems?
Yes — Carel EVD Evolution drivers, NTC/ratiometric probes and pGD terminals. Carel (Italy) equipment on R404A/R134a charges is supported with the fast-moving spares held at our Pretoria North workshop and non-stock items brought in on OEM order.
What pressure testing and gas compliance certificates are provided?
Every temperature mapping & validation job closes with a pressure test record and gas handling Certificate of Conformance issued under SANS 10147 by a SAQCC Gas registered technician, plus the HACCP documentation your auditors expect.
What operating envelope do you commission this equipment to?
Macadamia Processing run at +8 °C to +15 °C at 55–65% RH, with temperature mapping & validation performed against Client setpoint band, typically +2 °C to +8 °C. Moisture pickup drives rancidity and kernel downgrade
Related services & locations
- Temperature Mapping & Validation — Prospecton
- Temperature Mapping & Validation — Jacobs
- Temperature Mapping & Validation — Mobeni
- Temperature Mapping & Validation — Pinetown
- Temperature Mapping & Validation — New Germany
- Temperature Mapping & Validation — Westmead
- Copeland Temperature Mapping & Validation — Dube TradePort
- Citrus Packhouses — Dube TradePort
- Table Grape Packhouses — Dube TradePort
- Avocado Packhouses — Dube TradePort
- Banana Ripening Facilities — Dube TradePort
Get started
Schedule an on-site diagnostic in Dube TradePort
Tell us what you need cooled and where. We respond with a scoped quote, and for emergencies we dispatch straight away.
- Phone / WhatsApp
- 069 268 0988
- info@reyds.co.za
- Workshop
- 386 Eeufees Street, Pretoria North, Gauteng
- Hours
- Mon–Fri 07:00–17:00, Sat 08:00–13:00. 24/7 emergency breakdown line.