REYDSPackhouse & Cold Storage

Evapco · Gqeberha

Spray Foam Insulation for Evapco Systems in Mining & Bulk Air Cooling | Perseverance

Applied PU foam for roofs, tanks, pipework and irregular structures. We support Evapco evaporative condensers and cooling towers running R717, R744 in mining & bulk air cooling across Perseverance and Perseverance Industrial.

Technical highlights

SAQCC Gas certified spray foam insulation

SANS 10147 pressure and gas compliance, genuine Evapco OEM parts and rapid dispatch to Perseverance.

  • SAQCC Gas registered technicians handling R717, R744
  • SANS 10147 pressure vessel and installation compliance
  • Genuine Evapco OEM parts — Evapco spray nozzles, drift eliminators, fan drives and water treatment kits
  • 2–5 days per application to Perseverance, Gqeberha

Common maintenance vectors

What we find on these systems

  • Substrate moisture
  • Thickness consistency
  • UV protection on exposed foam
  • Scale fouling on coil surfaces in hard-water regions
  • Fan bearing failure from continuous high-ambient duty
  • Blocked bleed lines raising conductivity and corrosion

Dynamic specifications

Mining & Bulk Air Cooling duty on Evapco plant

Bulk air coolers, ice plants and surface chill dams

Typical system duty+2 °C to +12 °C chilled water (Applied thickness 25–150 mm)
Design humidity90–100% RH
Recommended gas / pressure classR717, R744 — handled by SAQCC Gas registered technicians
Equipment platformEvapco Evaporative condensers and cooling towers — Closed-circuit coolers, evaporative condensers, industrial ammonia packages
Compliance frameworksMHSA, SANS 10147, OHS Act, SAQCC Gas registration
OEM parts heldEvapco spray nozzles, drift eliminators, fan drives and water treatment kits
Service deliverableThickness and adhesion record
Response / lead time2–5 days per application
Location hubServing Perseverance Industrial and surrounds off the N2 / R335

Local context

Working in Perseverance

We service Perseverance Industrial and the surrounding blocks of Perseverance, Gqeberha, with access off the N2 and R335. Coastal salt-laden air plus wide day-night temperature swings demand coated coils and tight vapour barriers.

Bulk air coolers and ice plants for deep-level ventilation Underground heat stress limits shift productivity

Compliance

Documentation you receive

  • MHSA
  • SANS 10147
  • OHS Act
  • SAQCC Gas registration
  • Thickness and adhesion record

FAQ

Evapco spray foam insulation in Perseverance

How fast can a technician service Evapco equipment at a mining & bulk air cooling site in Perseverance?

Perseverance sits on the N2 and R335, so our Gqeberha dispatch reaches most Perseverance Industrial sites inside a standard callout window. Emergency spray foam insulation runs 24/7 because underground heat stress limits shift productivity.

Do you stock OEM components for Evapco systems?

Yes — Evapco spray nozzles, drift eliminators, fan drives and water treatment kits. Evapco (USA) equipment on R717/R744 charges is supported with the fast-moving spares held at our Pretoria North workshop and non-stock items brought in on OEM order.

What pressure testing and gas compliance certificates are provided?

Every spray foam insulation job closes with a pressure test record and gas handling Certificate of Conformance issued under SANS 10147 by a SAQCC Gas registered technician, plus the MHSA documentation your auditors expect.

What operating envelope do you commission this equipment to?

Mining & Bulk Air Cooling run at +2 °C to +12 °C chilled water at 90–100% RH, with spray foam insulation performed against Applied thickness 25–150 mm. Underground heat stress limits shift productivity

Get started

Schedule an on-site diagnostic in Perseverance

Tell us what you need cooled and where. We respond with a scoped quote, and for emergencies we dispatch straight away.

Phone / WhatsApp
069 268 0988
Email
info@reyds.co.za
Workshop
386 Eeufees Street, Pretoria North, Gauteng
Hours
Mon–Fri 07:00–17:00, Sat 08:00–13:00. 24/7 emergency breakdown line.