REYDSPackhouse & Cold Storage

Alfa Laval · Camperdown

Glycol Chiller Installation for Alfa Laval Systems in Macadamia Processing | Camperdown

Glycol and ice-water plant for process and brewery cooling loops. We support Alfa Laval plate heat exchangers and air coolers running R404A, R134a in macadamia processing across Camperdown and Camperdown Industrial.

Technical highlights

SAQCC Gas certified glycol chiller installation

SANS 10147 pressure and gas compliance, genuine Alfa Laval OEM parts and rapid dispatch to Camperdown.

  • SAQCC Gas registered technicians handling R404A, R134a
  • SANS 10147 pressure vessel and installation compliance
  • Genuine Alfa Laval OEM parts — Alfa Laval plate packs, gaskets and cleaning-in-place chemistry
  • 4–10 weeks to Camperdown, Camperdown

Common maintenance vectors

What we find on these systems

  • Glycol concentration drift
  • Loop air locking
  • Pump head mismatch
  • Plate fouling reducing approach temperature
  • Gasket hardening on semi-welded units
  • Freeze damage after low-flow glycol events

Dynamic specifications

Macadamia Processing duty on Alfa Laval plant

Dry-store climate control and kernel holding rooms

Typical system duty+8 °C to +15 °C (−8 °C to +4 °C glycol supply)
Design humidity55–65% RH
Recommended gas / pressure classR404A, R134a — handled by SAQCC Gas registered technicians
Equipment platformAlfa Laval Plate heat exchangers and air coolers — Brazed and semi-welded plate exchangers, industrial air units
Compliance frameworksHACCP, FSSC 22000, SANS 10147, SAQCC Gas registration
OEM parts heldAlfa Laval plate packs, gaskets and cleaning-in-place chemistry
Service deliverableLoop balance and concentration record
Response / lead time4–10 weeks
Location hubServing Camperdown Industrial and surrounds off the N3 / R603

Local context

Working in Camperdown

We service Camperdown Industrial and the surrounding blocks of Camperdown, Camperdown, with access off the N3 and R603. Sub-tropical coastal humidity keeps wet-bulb temperatures high year-round, which raises evaporative condenser duty and accelerates coil corrosion.

Dehumidification-dominant load with low sensible duty Moisture pickup drives rancidity and kernel downgrade

Compliance

Documentation you receive

  • HACCP
  • FSSC 22000
  • SANS 10147
  • SAQCC Gas registration
  • Loop balance and concentration record

FAQ

Alfa Laval glycol chiller installation in Camperdown

How fast can a technician service Alfa Laval equipment at a macadamia processing site in Camperdown?

Camperdown sits on the N3 and R603, so our Camperdown dispatch reaches most Camperdown Industrial sites inside a standard callout window. Emergency glycol chiller installation runs 24/7 because moisture pickup drives rancidity and kernel downgrade.

Do you stock OEM components for Alfa Laval systems?

Yes — Alfa Laval plate packs, gaskets and cleaning-in-place chemistry. Alfa Laval (Sweden) equipment on R404A/R134a charges is supported with the fast-moving spares held at our Pretoria North workshop and non-stock items brought in on OEM order.

What pressure testing and gas compliance certificates are provided?

Every glycol chiller installation job closes with a pressure test record and gas handling Certificate of Conformance issued under SANS 10147 by a SAQCC Gas registered technician, plus the HACCP documentation your auditors expect.

What operating envelope do you commission this equipment to?

Macadamia Processing run at +8 °C to +15 °C at 55–65% RH, with glycol chiller installation performed against −8 °C to +4 °C glycol supply. Moisture pickup drives rancidity and kernel downgrade

Get started

Schedule an on-site diagnostic in Camperdown

Tell us what you need cooled and where. We respond with a scoped quote, and for emergencies we dispatch straight away.

Phone / WhatsApp
069 268 0988
Email
info@reyds.co.za
Workshop
386 Eeufees Street, Pretoria North, Gauteng
Hours
Mon–Fri 07:00–17:00, Sat 08:00–13:00. 24/7 emergency breakdown line.