REYDSPackhouse & Cold Storage

Isocab · Kempton Park

Cold Room Construction for Isocab Systems in Pharmaceutical Distribution | Isando

Insulated panel cold rooms built, sealed and commissioned as one contract. We support Isocab high-performance insulated panels and doors running R744 in pharmaceutical distribution across Isando and Isando Industrial.

Technical highlights

SAQCC Gas certified cold room construction

SANS 10147 pressure and gas compliance, genuine Isocab OEM parts and rapid dispatch to Isando.

  • SAQCC Gas registered technicians handling R744
  • SANS 10147 pressure vessel and installation compliance
  • Genuine Isocab OEM parts — Isocab panel joints, door sets and hygienic coving
  • 3–6 weeks per room to Isando, Kempton Park

Common maintenance vectors

What we find on these systems

  • Panel joint sealing
  • Vapour barrier continuity
  • Floor junction thermal bridging
  • Vapour barrier punctures leading to core wetting
  • Thermal bridging at unsealed floor junctions
  • Panel skin delamination after impact damage

Dynamic specifications

Pharmaceutical Distribution duty on Isocab plant

Validated cold rooms, redundant plant and mapped storage

Typical system duty+2 °C to +8 °C (−2 °C to +12 °C room design)
Design humidity45–65% RH
Recommended gas / pressure classR744 — handled by SAQCC Gas registered technicians
Equipment platformIsocab High-performance insulated panels and doors — PIR and PUR panel systems with fire-rated cores
Compliance frameworksSAHPRA GDP, GxP validation, ISO 22000, SANS 10147, SAQCC Gas registration
OEM parts heldIsocab panel joints, door sets and hygienic coving
Service deliverableHeat load calculation and commissioning report
Response / lead time3–6 weeks per room
Location hubServing Isando Industrial and surrounds off the R21 / N12

Local context

Working in Isando

We service Isando Industrial and the surrounding blocks of Isando, Kempton Park, with access off the R21 and N12. Highveld summers push afternoon ambients past 32 °C with heavy thunderstorm humidity, so condensers here are sized with a generous approach and cleaned before every summer.

Redundant N+1 plant with continuous mapped monitoring Any excursion outside 2–8 °C requires quarantine and investigation

Compliance

Documentation you receive

  • SAHPRA GDP
  • GxP validation
  • ISO 22000
  • SANS 10147
  • SAQCC Gas registration
  • Heat load calculation and commissioning report

FAQ

Isocab cold room construction in Isando

How fast can a technician service Isocab equipment at a pharmaceutical distribution site in Isando?

Isando sits on the R21 and N12, so our Kempton Park dispatch reaches most Isando Industrial sites inside a standard callout window. Emergency cold room construction runs 24/7 because any excursion outside 2–8 °c requires quarantine and investigation.

Do you stock OEM components for Isocab systems?

Yes — Isocab panel joints, door sets and hygienic coving. Isocab (Belgium) equipment on R744 charges is supported with the fast-moving spares held at our Pretoria North workshop and non-stock items brought in on OEM order.

What pressure testing and gas compliance certificates are provided?

Every cold room construction job closes with a pressure test record and gas handling Certificate of Conformance issued under SANS 10147 by a SAQCC Gas registered technician, plus the SAHPRA GDP documentation your auditors expect.

What operating envelope do you commission this equipment to?

Pharmaceutical Distribution run at +2 °C to +8 °C at 45–65% RH, with cold room construction performed against −2 °C to +12 °C room design. Any excursion outside 2–8 °C requires quarantine and investigation

Get started

Schedule an on-site diagnostic in Isando

Tell us what you need cooled and where. We respond with a scoped quote, and for emergencies we dispatch straight away.

Phone / WhatsApp
069 268 0988
Email
info@reyds.co.za
Workshop
386 Eeufees Street, Pretoria North, Gauteng
Hours
Mon–Fri 07:00–17:00, Sat 08:00–13:00. 24/7 emergency breakdown line.
CallWhatsAppGet Quote069 268 0988