REYDSPackhouse & Cold Storage

Bethlehem

CO₂ Transcritical Service in Bethlehem Industrial

Service and fault-finding on transcritical CO₂ racks up to 120 bar. We cover Bethlehem Industrial off the N5 and R26.

Scope

Service detail

Dry heat by day and sharp frost by night stress door heaters, oil viscosity and defrost timing in equal measure.

Disciplinegas
Design duty−35 °C evaporating, 90–120 bar high side
DeliverableHigh-side pressure log and control parameter record
TurnaroundSpecialist dispatch within 24 hours
Typical findingsGas cooler pressure control; Standstill pressure management; Flash gas bypass valve tuning
CoverageBethlehem Industrial, Bethlehem — N5 / R26

FAQ

CO₂ Transcritical Service in Bethlehem Industrial

How quickly can Reyds attend Bethlehem Industrial?

Our technicians route to Bethlehem Industrial via the N5 and R26, with specialist dispatch within 24 hours on co₂ transcritical service and 24/7 breakdown cover for critical plant.

What does the job hand over?

High-side pressure log and control parameter record, plus a SANS 10147 gas handling Certificate of Conformance issued by a SAQCC Gas registered technician.

Get started

Request a quote or site assessment

Tell us what you need cooled and where. We respond with a scoped quote, and for emergencies we dispatch straight away.

Phone / WhatsApp
069 268 0988
Email
info@reyds.co.za
Workshop
386 Eeufees Street, Pretoria North, Gauteng
Hours
Mon–Fri 07:00–17:00, Sat 08:00–13:00. 24/7 emergency breakdown line.
CallWhatsAppGet Quote069 268 0988